Model No.: 6-CNF-200

Maintenance Free Energy Storage Battery 12V 200AH Lead Storage Battery
 
 
<table align="left" bo

Maintenance Free Energy Storage Battery 12V 200AH Lead Storage Battery

 

 

Nominal Voltage 12V
Nominal Capacity (C20) 200Ah (10.8V,at 25)
Dimension Length 520mm
Width 240mm
Height 230mm
Total Height 230mm
Weight Approx. 62.50 kg
Terminal Cable of φ6mm
Internal Resistance Approx. 4 mΩ (25)
Max Short-duration Discharge Current 4000A(25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

Designed life is 5~8 years (20);

High tin alloy, imported colloid electrolyte and special lead plaster;

Wide temperature scope of application (-30~45);

Best temperature of application (20±5);

No leaking, safe and reliable;

Standing or lying down for using, convenient to transport and install;

Good performance on long-term insufficient charge and frequency discharge;

The battery with unique waterproof technical treatment cables ensure the stable operation of solar street lamp products.

Low self-discharge rate.

 

Applications:

Energy Storage

Automotive

Telecommunication

Banks & Financial Centre

Hospital& Testing Laboratories

Emergency Power System

Alarm & Security system

High Power Backup Supply

Power systems

 

STORAGE

Batteries should be stored in dry and clean warehouse which has good air exchange system. Batteries should avoid direct sunlight. Batteries should not be near to heat (such as radiator, the distance should more than1m). Batteries should avoid any toxic gas and organic solvent.

When the ambient temperature is less than 25, the longest storage life is 6 months.

Batteries should be recharged within the storage life or before using.

Charging methods: maximum charging current 8A, constant voltage 2.45±0.05V/cell (25);

Charging time: 15~20h; Temperature compensation coefficient: -5mV//cell.

 

TECHNICAL FEATURES:

• Sealed Construction

The unique construction and use waterproof battery cable to offer reliable guarantee for stable operation of solar street lamp products.

 

• Electrolyte Suspension System

All batteries utilize an electrolyte suspension system consisting of a high porosity, glass fiber material which in conjunction with plates, totally absorb and contain the electrolyte.

 

• Gas Recombination

CGB batteries incorporate a built-in design that controls gas generation and induces recombination of more than 99% of gases generated during float or cyclic usage.

 

• Maintenance Free Operation

There is no need to check specific gravity of the electrolyte or add water to batteries during float service life. In fact, there is no provision for this type of maintenance.

 

• Low Pressure Valve Regulated System..

All batteries are equipped with safety release valves, designed to operate between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is never an excessive accumulation of gas within the battery.

 

• Heavy Duty Grids

Heavy duty lead calcium tin alloy grids provide an extra margin of performance and service life in either float or cyclic applications.

 

• Self Discharge - Shelf Life

The self discharge rate at room temperature is approximately 3% of rated capacity per month.

 

• Operating Temperature

CGB Batteries may be operated over a broad range of ambient temperatures.

 

• Deep Discharge Recovery

The batteries recover their capacities even after repeated deep discharges.

 

Services:

CGB service technicians are factory trained to design, test, install and service any stored energy solution for industrial applications. Our experts can help with planning, engineering, project supervision, certification, grounding surveys, and warehousing and fleet management. We also provide data analysis, equipment testing, and charger efficiency testing.

 

Warning

• Replacement of battery shall be performed as per following order. If failed, it may cause fire and explosion. Remove cable from negative terminal first.Connect cable to negative terminal last.

• When connect cable to battery, make sure not to get changed post of +and -. It may cause the damage of electronic components or fire.

• When ueing the battery ,handle with care,sulfuric acid may cause blindness or severe burn.

 

Caution

• When moving battery, be careful not to drop the battery , which is heavy, Do not shake the battery with handle, if there is the handle, It may cause the injury.

• Do not shore the battery at the following places. High temperature and humidity. Being exposed to rain,snow, direct sunshine.

bigPhoto
 Mr. Mr. Gao song

Tel: 86-27-84891323
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Wuhan Changguang Battery Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Wuhan
Province/State: Hubei
Country/Region: China (Mainland)

You May Like:

Product (65)